III -   OPERATING MODES
Nominal operation:
The BSI calculates  the "range"  with the  fuel consumption  and the amount  of fuel
remaining supplied by the control panel.
After acquiring  the signal from  the speed sensor, the  BSI calculates  the following
parameters:
"journey distance" since last reset,
"average journey consumption" since last reset,
"instantaneous consumption"  with fuel  flow information  supplied by the  engine
management ECU,
"average journey speed" since last reset,
the BSI encodes this  information in VAN frames  to be sent to the  control panel.
The multifunction screen displays them.
Reset:
Pressing  the on-board  ECU  switch  for a  long  time on  the  steering  wheel stalk
resets the journey counters.
The BSI encodes this status on a VAN frame to be  sent to the multifunction screen
of the control panel.