IV -   THE VAN PROTOCOL
The network consists of 2 wires, called:
Data,
Data B (Data bar).
The  Data  B  wire  is  so  called  because  the  voltage  at  its  terminals  is  always
opposite to the voltage on Data.
5V
Data
0V
t
5V
Data B
0V
t
Two current levels are used to encode two distinct logical states.
This process is used to:
limit the radiation given off,
provide good resistance to interference.
There is an  advantage in using these two  wires and electronic circuits  for emitting
and receiving  signals. It allows operation  in downgraded mode  if one of the  wires
is broken or short circuited to +12V or to earth.
If a wire breaks, the  electronics compares the current level of the signal  compared
to a reference. The electronics signals the data line faults.