160
Chapter 2
B - EVAPORATOR ICING UP SAFETY DEVICE
The evaporator icing up safety device defines the rules for engaging and
cutting off the compressor depending on:
•
•
evaporator temperature,
external temperature.
Evaporator temperature as a function of external temperature:
B
2
-6°C
10°C
20°C
40°C
A
0
1
-2°C
KEY
A
B
1
External air temperature
Evaporator temperature
Compressor forbidden
Compressor authorised
2
MULTIPLEXED BSI - XSARA PICASSO AND XSARA – PART 8
©