II -    ADDITIONAL ELECTRIC HEATING FUNCTION
Function:
For  DW10TD engines  (HDi),  heating resistors  are  placed  in the  engine  cooling
circuit.  This  allows  a  sufficient  heat  source  to  be  obtained  to  operate  the  air
conditioning, despite the slow rise in engine temperature.
Functional description:
The  engine  ECU  requests  the   additional  heating  depending  on  the   following
information:
coolant temperature,
external temperature (through engine inlet).
Note:  an additional heater is available as  an option.
III -   DE-ICING FUNCTION
Function:
To de-ice the heated rear screen and the heated door mirrors depending on:
user request,
energy management (12 minute timer),
engine running information.
Functional description:
Action
De-icing of the rear screen and door mirrors for  12 minutes
IF condition     The user requests de-icing
AND condition  The engine is  running
Display
Illumination of the de-icing LED
Case of switching off the engine during the timer
If the engine is started again within one minute after switching  it off:
De-icing is reactivated to finish the timer.
If the engine is started again more than  one minute after switching it off:
De-icing is not reactivated.
MULTIPLEXED BSI - XSARA PICASSO AND XSARA – PART 8
©
AUTOMOBILES CITROËN Toute reproduction ou traduction même partielle sans  l'autorisation écrite d'AUTOMOBILES CITROËN est interdite et constitue une contrefaçon
Product Specification
CategoriesCitroën Manuals, Citroën Picasso Manuals, Citroën Xsara Manuals
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 228 pages
Document File TypePDF
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field