164
Chapter 2
II - ADDITIONAL ELECTRIC HEATING FUNCTION
Function:
For DW10TD engines (HDi), heating resistors are placed in the engine cooling
circuit. This allows a sufficient heat source to be obtained to operate the air
conditioning, despite the slow rise in engine temperature.
Functional description:
The engine ECU requests the additional heating depending on the following
information:
•
•
coolant temperature,
external temperature (through engine inlet).
Note: an additional heater is available as an option.
III - DE-ICING FUNCTION
Function:
To de-ice the heated rear screen and the heated door mirrors depending on:
•
•
•
user request,
energy management (12 minute timer),
engine running information.
Functional description:
Action
De-icing of the rear screen and door mirrors for 12 minutes
IF condition The user requests de-icing
AND condition The engine is running
Display
Illumination of the de-icing LED
Case of switching off the engine during the timer
•
•
If the engine is started again within one minute after switching it off:
De-icing is reactivated to finish the timer.
If the engine is started again more than one minute after switching it off:
De-icing is not reactivated.