AIR CONDITIONING
REFRIGERANT RECOVERY, RECYCLING,
RECHARGING
8.  Close valves on refrigerant station.
9.  Turn Main switch to ’OFF’.
10.
Close valves on connectors.
11.  Disconnect high and low pressure hoses from
connectors.
Service repair no - 82.30.02
WARNING: The air conditioning system is
charged with a high pressure, potentially
toxic refrigerant. Repairs or servicing must
only be carried out by an operator familiar with
both the vehicle system and the charging and
testing equipment.
12.  Fit dust caps to connectors.
13.  Open tap at rear of station to drain refrigerant oil
recovered from system.
14.  Measure and record quantity of refrigerant oil
recovered from system.
15.  Close tap at rear of station.
WARNING: All operations must be carried
out in a well ventillated area away from
open flame and heat sources.
Evacuation
CAUTION: Whenever the refrigerant
system is opened, the receiver/drier must
be renewed immediately before evacuating
and recharging the system.
WARNING: Wear eye and hand safety
protection.
CAUTION: Overcharging air conditioning
system will cause excessive head
pressure.
1.  Remove dust caps from high and low pressure
connectors.
2.  Connect high and low pressure hoses to
appropriate connections.
An air conditioning portable Refrigerant Recovery
Recycling Recharging Station for use with R134a
refrigerant incorporates all the features necessary to
recover R134a refrigerant from the air conditioning
system; to filter and remove moisture; to evacuate and
recharge with the reclaimed refrigerant. The unit can
also be used for performance testing and air
conditioning system analysis.
3.  Open valves on connectors.
4.  Turn valves on refrigerant station to correct
positions.
5.  Turn Process switch to correct position.
6.  Turn Main switch to ’ON’.
7.  Allow station to evacuate system.
NOTE: If the vacuum reading is below
700mmHg
after 15 minutes, suspect a leak
The operator must adhere to the equipment
manufacturer’s instructions.
in the system. Partially recharge the
system and check for leaks using an electronic
leak tester. Check suction lines first, then run the
compressor for 5 minutes. Next check the high
pressure lines.
Refrigerant Recovery
1.
2.
Remove dust caps from high and low pressure
connectors.
Connect high and low pressure hoses to
appropriate connections.
Open valves on connectors.
Turn valves on refrigerant station to correct
positions.
NOTE: The system must be evacuated
immediately before recharging
commences. Delay between evacuation
and recharging is not permitted.
3.
4.
NOTE: Operate the refrigerant station in
accordance with the manufacturers
instructions.
5.
6.
7.
Turn Process switch to correct position.
Turn Main switch to ’ON’.
Allow station to recover refrigerant from system.
ADJUSTMENT
1
Product Specification
CategoriesLand Rover, Land Rover Defender
Tags
Model Year1999, 2000, 2001, 2002
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 627 pages
Document TypeWorkshop Manual
LanguageEnglish
Product NameDefender
Product BrandLand Rover
Document File TypePDF
Publisherlandrover.com
Wikipedia's Pagehttp://en.wikipedia.org/wiki/Land_Rover
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field