AIR CONDITIONING
CONDENSER FANS AND MOTORS
Service repair no - 82.15.01 - Motor
Service repair no - 82.15.03 - Fan
Remove
1.
Remove condenser assembly. See Condenser
12.
Disconnect receiver/drier pipes at condenser
unions.
13.
14.
Remove retaining bracket from side pipe.
Remove LH pipe from condenser and discard ’O’
ring.
15.
16.
Remove 2 screws securing receiver/drier
bracket.
Release pipes from lower clips and remove
receiver/drier assembly.
2. Remove 4 bolts securing fan cowl to condenser.
3. Remove 3 bolts securing fan motor to cowl.
4. Remove fan motor assembly.
5. Remove 3 screws securing fan blades to motor.
6. Remove fan blades.
17.
18.
Remove ’O’ ring from RH pipe
Remove 2 screws securing lower end of each
fan motor.
Remove 2 bolts and remove condenser lower
mounting bracket.
Remove 2 bolts and securing condenser upper
mounting bracket.
Remove upper mounting bracket and fan motor
assembly.
Remove 2 screws securing each side mounting
bracket and remove the brackets.
Transfer parts removed to new condenser.
Add 40 ml of refrigerant oil to new compressor to
compensate for oil loss.
19.
20.
21.
22.
Refit
7. Reverse removal procedure. Ensuring that wiring
is clipped and no fouling of fan blade can occur.
23.
24.
Refit
25.
26.
Reverse removal procedure. 3 to 11.
Evacuate and recharge air conditioning system.
See Adjustment, Refrigerant Recovery
Recycling Recharging
27.
28.
Carry out leak test on disturbed joints. See
Adjustment, Leak Test System
Check air conditioning operation by carrying out
a System Test. See Adjustment, System Test
REPAIR
7
Product Specification
Categories | Range Rover |
---|---|
Tags | Land Rover |
Model Year | 1998 |
Download File |
|
Document Type | Workshop Manual |
Language | English |
Product Brand | Land Rover |
Document File Type | |
Publisher | landrover.com |
Wikipedia's Page | http://en.wikipedia.org/wiki/Land_Rover |
Copyright | Attribution Non-commercial |