1995 Land Rover Discovery Workshop Manual

17
EMISSION CONTROL
HEATED OXYGEN SENSOR (HO2S)
Service repair no - 19.26.16
PURGE CONTROL VALVE
Service repair no - 17.15.39
Remove
CAUTION: The removal of the sensors
from the exhaust system must only be
carried out when the engine is cold.
1.  Disconnect battery negative lead.
Remove
1.
2.
3.
Disconnect battery negative lead.
Disconnect the electrical plugs from the sensors.
Unscrew and remove the sensors from the two
exhaust downpipes.
2.
3.
4.
5.
Disconnect multiplug from purge control valve.
Release clip and disconnect hose from valve.
Release valve from charcoal canister.
Remove valve.
Refit
4.
Coat the threads of the sensors with anti-seize
compound.
CAUTION: To ensure that the efficiency of
the sensor is not impaired, DO NOT allow
anti-seize compound to come into contact
with the sensor nose.
6.
Discard ’O’ ring.
5.
6.
Screw in the sensor and tighten to the correct
torque using special tool LST134.
Connect the electrical plugs and battery lead.
Refit
7.
8.
9.
Clean valve and valve location.
Fit new ’O’ ring to purge valve.
Position and secure valve to charcoal canister.
Connect hose to purge valve and secure with
clip.
10.
11.
12.
Connect multiplug to valve.
Reconnect battery negative lead.
2
REPAIR
Product Specification
CategoriesLand Rover Discovery, Range Rover
Tags
Model Year1995
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 873 pages
Document TypeWorkshop Manual
LanguageEnglish
Product NameDiscovery
Product BrandLand Rover
Document File TypePDF
Publisherlandrover.com
Wikipedia's Pagehttp://en.wikipedia.org/wiki/Land_Rover
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field