26
COOLING SYSTEM
THERMOSTATIC SENSOR
Service repair no - 19.22.18
Remove
THERMOSTAT
Service repair no - 26.45.01
Remove
1.
2.
Disconnect Lucar connector from sensor.
Remove sensor.
1. Position suitable container to collect coolant.
2. Slacken 2 clips and release radiator top hose.
3.
4.
5.
Release bypass hose from securing bracket.
Release top hose from securing bracket.
Remove top hose.
Refit
3.
4.
5.
6.
7.
Clean sensor.
Apply Loctite 405 to threads of sensor.
Fit sensor and tighten to 15Nm
Connect Lucar to sensor.
Top-up cooling system.