EMISSION CONTROL - V8
Test 2 – Secondary Air Injection (SAI) Control Valves
5
6
2
1
4
3
M17 0376
1
2
3
SAI control valve
Pressure connection
Outlet
4 Inlet connection stopper
5 Hand pressure pump
6 Hand vacuum pump
Visually inspect the SAI control valve for external damage.
Leak Test
Remove the line from the inlet connection and connect the hand pressure pump (5) using the inlet connection stopper
2
(4). Using the hand pressure pump, pressurise the SAI control valve with 100 mBar (1.45 lbf/in ) pressure. Maximum
2
permissable pressure drop at the hand pressure pump gauge 10 mbar/minute (0.145 lbf/in /minute) with the outlet (3)
open.
Valve Opening Test
Connect the hand vacuum pump (6) to the control pressure connection (2). Depressurise the pressure connection
2
using the hand vacuum pump. When the vacuum reaches -300 mbar (-4.35 lbf/in ), the SAI control valve (1) must
open and the pressure on the hand pressure pump (5) gauge should drop suddenly.
Tightness of Diaphragms
The available pressure difference (vacuum) at the control pressure connection (2) must not drop over a period of time
(Refer to Valve Opening Test).
NOTE: In the case of a leaking or incorrectly controlled SAI control valve, the inlet connection is usually heavily fouled
and a condensate smell is noticeable on the hose line to the SAI pump.
If, after switching off the SAI pump, pulsation noise is still noticeable at the SAI pump, the SAI control valve and
delivery hoses must be replaced before fitting a new SAI pump.
17-2-48
DESCRIPTION AND OPERATION
Product Specification
Categories | Land Rover Defender, Land Rover Discovery II, Range Rover |
---|---|
Tags | Land Rover |
Model Year | 1999 |
Download File |
|
Document Type | Workshop Manual |
Language | English |
Product Name | Discovery Series II |
Product Brand | Land Rover |
Document File Type | |
Publisher | landrover.com |
Wikipedia's Page | http://en.wikipedia.org/wiki/Land_Rover |
Copyright | Attribution Non-commercial |